  • SPOTLIGHT CASE
  •  
  • CE/MOC
David J. Lucier, MD, MBA, MPH, and Jeffrey L. Greenwald, MD, September 2018
An older woman with lung cancer that had metastasized to the brain was admitted to the hospital and found to have Pneumocystis jiroveci pneumonia (PJP pneumonia), invasive pulmonary aspergillus, diffuse myopathy, and gastrointestinal bleeding. Medication reconciliation revealed that she had been prescribed a high dose of dexamethasone to reduce the brain swelling associated with the cancer. Although the intention had been to taper the steroids after she received radiotherapy for her brain metastases, the corticosteroids were never tapered, and she continued to take high-dose steroids for more than 2 months. Physicians believed that all of her acute issues were a result of the mistakenly high dose of the steroids.
Jason Bergsbaken, PharmD, September 2018
A woman with cancer was admitted to begin a chemotherapy cycle of IV etoposide (daily for 3 days) and IV cisplatin (single dose). At the hospital's cancer center satellite pharmacy, the pharmacist entered the order into the computer and prepared the first dose of the medications. While transcribing the order, the pharmacist inadvertently switched the duration of therapy for the two agents. The transposition did not affect the patient's first day of therapy. The second day fell on a Saturday, when the satellite pharmacy was closed; a different pharmacist who did not have access to the original chemotherapy order prepared the therapy order. Cisplatin was labeled, dispensed, and reached the bedside. The nurse bypassed the double-check policy for verifying the order prior to administration, and the patient received the second dose of cisplatin instead of the intended dose of etoposide.
Jessica Katznelson, MD, September 2018
In a simulated cardiac resuscitation case of a 5-year-old boy found pulseless and apneic in the bathtub by a parent, many interprofessional teams had difficulty with resuscitation due to a lack of interoperability between the prestocked disposable laryngoscope blades and handles on the Broselow cart (a proprietary system designed to facilitate finding appropriate-sized equipment for pediatric patients requiring lifesaving interventions) with the emergency department's actual stock of blades and handles. This incompatibility led to significant delays and some failures to intubate. Teams often did not recognize the incompatibility and spent unnecessary time replacing batteries while others called for backup airway teams.

No hay comentarios: