sábado, 10 de diciembre de 2011

Transitioning between electronic health rec... [J Gen Intern Med. 2011] - PubMed - NCBI

J Gen Intern Med. 2011 Aug;26(8):868-74. Epub 2011 Apr 16.

Transitioning between electronic health records: effects on ambulatory prescribing safety.

Source

Department of Pediatrics, Weill Cornell Medical College, New York, NY 10065, USA. err9009@med.cornell.edu

Abstract

BACKGROUND:

Healthcare providers previously using older electronic health records (EHRs) with electronic prescribing (e-prescribing) are transitioning to newer systems to be eligible for federal meaningful use incentives. Little is known about the safety effects of transitioning between systems.

OBJECTIVE:

To assess the effect of transitioning between EHR systems on rates and types of prescribing errors, as well as provider perceptions about the effect on prescribing safety.

DESIGN, PARTICIPANTS:

Prospective, case study of 17 physicians at an academic-affiliated ambulatory clinic from February 2008 through August 2009. All physicians transitioned from an older EHR with minimal clinical decision support (CDS) for e-prescribing to a newer EHR with more robust CDS.

MAIN MEASUREMENTS:

Prescribing errors were identified by standardized prescription and chart review. A novel survey instrument was administered to evaluate provider perceptions about prescribing safety.

KEY RESULTS:

We analyzed 1298 prescriptions at baseline, 1331 prescriptions 12 weeks post-implementation, and 1303 prescriptions one year post-implementation. Overall prescribing error rates were highest at baseline (35.7 per 100 prescriptions, 95% confidence interval (CI) 23.2-54.8) and lowest one year post-implementation (12.2 per 100 prescriptions, 95% CI 8.6-17.4) (p < 0.001). Improvement in prescribing safety was mainly a result of reducing inappropriate abbreviation errors. However, rates for non-abbreviation prescribing errors were significantly higher at 12 weeks post-implementation than at baseline (17.7 per 100 prescriptions, 95% CI 9.5-33.0 versus 8.5 per 100 prescriptions, 95% CI 4.6-15.9) (p <0.001) and no different at baseline than one year (10.2 per 100 prescriptions, 95% CI 6.2-18.6) (p = 0.337). Survey results complemented quantitative findings.

CONCLUSIONS:

Results from this case study suggest that transitioning between systems, even to those with more robust CDS, may pose important safety threats. Recognizing the challenges associated with transitions and refining CDS within systems may help maximize safety benefits.

PMID:
21499828
[PubMed - in process]
PMCID: PMC3138980
[Available on 2012/8/1]
Transitioning between electronic health rec... [J Gen Intern Med. 2011] - PubMed - NCBI

No hay comentarios: