viernes, 16 de diciembre de 2016

Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts | BMC Medical Imaging | Full Text

Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts | BMC Medical Imaging | Full Text
Biomed Central

BMC Medical Imaging

Impact of region-of-interest method on quantitative analysis of DTI data in the optic tracts

  • Ylva LiljaEmail author,
  • Oscar Gustafsson,
  • Maria Ljungberg,
  • Daniel Nilsson and
  • Göran Starck
BMC Medical ImagingBMC series – open, inclusive and trusted201616:42
DOI: 10.1186/s12880-016-0145-9
Received: 18 January 2016
Accepted: 14 June 2016
Published: 11 July 2016

Abstract

Background

To extract DTI parameters from a specific structure, a region of interest (ROI) must be defined. ROI selection in small structures is challenging; the final measurement results could be affected due to the significant impact of small geometrical errors. In this study the optic tracts were analyzed with the aim to assess differences in DTI parameters due to ROI method and to identify the most reliable method.

Methods

Images of 20 healthy subjects were acquired. Fractional anisotropy (FA) was extracted from the optic tracts by four different ROI methods. Manual tracing was performed in 1) the b0 image and 2) a T1-weighted image registered to the FA image. Semi-automatic segmentation was performed based on 3) tractography and 4) the FA-skeleton algorithm in the tract-based spatial statistics (TBSS) framework. Results were analyzed with regard to ROI method as well as to inter-scan, intra-rater and inter-rater reliability.

Results

The resulting FA values divided the ROI methods into two groups that differed significantly: 1) the FA-skeleton and the b0 methods showed higher FA values compared to 2) the tractography and the T1-weighted methods. The intra- and inter-rater variabilities were similar for all methods, except for the tractography method where the inter-rater variability was higher. The FA-skeleton method had a better reproducibility than the other methods.

Conclusion

Choice of ROI method was found to be highly influential on FA values when the optic tracts were analyzed. The FA-skeleton method performed the best, yielding low variability and high repeatability.